PREFORMED INSULATING PANEL

Description:

Preformed insulating panel for underfloor heating made of EPS.

Complies with EN-1264 standard for installation on heated premises.

Suitable for pipes from 16 to 18 mm in diameter, installation in multiples of 75mm.

Connection between panels by interlocking.

Surface area 1.215m².

Dimensions: 1350 x 900 x 23mm.

Technical Data:

  • Usable pipe diameter: Ø 16÷18 mm
  • Installation pitch: multiples of 75 mm
  • Flexural strength (KPa): ≥ 150
  • Compression stress (σ10) – (KPa): ≥ 100
  • Permanent compression creep (KPa): CC(2/1.5/50)30
  • Tensile strength (KPa): ≥ 200
  • Density: 22 kg/m³
  • Water absorption (%): ≤ 1
  • Water vapor permeability (δ) (mg/Pa·h·m): 0.009 – 0.02
  • Fire reaction: EUROCLASS E

Storage Conditions:

  • Panels should not be exposed to direct sunlight
  • Thermal storage conditions should be between 5°C and 50°C
  • Panels should not come into contact with chemical agents
  • Keep panels away from flames, sparks, welding drips, or any heat source.

Warning:

Keep the product dry and protected from sunlight before, during, and after installation, until it is covered by the mortar.

Notes:

  • Usable pipe diameter: Refers to the range of pipe diameters that the panel is designed to accommodate.
  • Installation pitch: Refers to the spacing between pipes when they are installed on the panel.
  • Flexural strength: Measures the panel’s ability to resist bending.
  • Compression stress: Measures the panel’s ability to withstand compressive forces.
  • Permanent compression creep: Measures the panel’s long-term deformation under sustained compressive load.
  • Tensile strength: Measures the panel’s ability to resist being pulled apart.
  • Density: This is a measure of the panel’s mass per unit volume.
  • Water absorption: Measures the amount of water the panel can absorb.
  • Water vapour permeability: This measures the amount of water vapour that can pass through the panel.